OILCAP 158 Oil Detector
The Oil Contamination Alarm, model OILCAP 158, measures capacitance between its rod and the walls of the water tank. A lower capacitance indicates a higher oil concentration in the water. The OILCAP 158 features an adjustable alarm limit; when capacitance drops below the set threshold (indicating increased oil concentration), it activates a relay with opening and closing contacts after a 1-second delay. If capacitance rises above the set value (indicating decreased oil concentration), the relay deactivates after an adjustable delay ranging from 0 to 30 seconds, in 2-second increments. Additionally, the OILCAP 158 includes an alarm relay to signal power failure.
Key Features
- Capacitance Measurement: Monitors capacitance between the rod and tank walls to detect oil concentration.
- Adjustable Alarm Limit: Customizable alarm threshold for detecting high oil levels.
- Quick Relay Activation: Activates a relay with a 1-second delay when oil concentration rises above the set limit.
- Adjustable Deactivation Delay: Relay deactivates after an adjustable delay of 0 to 30 seconds when oil concentration falls.
- Power Failure Alert: Includes an alarm relay to indicate power failures.
- Multiple Relay Outputs: Features Normally Closed (NC) and Normally Open (NO) outputs for versatile alerting options.
- Simple Configuration: Easy 15-step alarm level and delay settings using DIP switches.
- LED Status Indicators: Visual indicators for measured level, alarm limit, delay settings, and relay status.
- Wide Power Supply Range: Operates on a power supply of 100 VAC to 230 VAC for compatibility.
Benefits
- Effective Oil Detection: Accurately monitors oil concentration in water tanks, ensuring early detection of contamination.
- Customizable Alerts: Adjustable alarm limits allow for tailored sensitivity based on specific operational needs.
- Prompt Response: Quick relay activation ensures timely alerts, enabling rapid response to potential oil spills.
- Flexible Delay Settings: Adjustable deactivation delay helps reduce false alarms and allows for stable readings in varying conditions.
- Enhanced Safety: Power failure alarm ensures that operators are informed of any disruptions, maintaining safety standards.
- Versatile Output Options: Normally Closed (NC) and Normally Open (NO) relay outputs provide flexibility in integrating with existing systems.
- User-Friendly Configuration: Simple DIP switch settings enable easy adjustment of alarm levels and delays, facilitating user operation.
- Visual Monitoring: LED indicators provide clear, real-time information on measured levels and alarm statuses, improving situational awareness.
- Wide Compatibility: Operates within a broad power supply range (100 VAC to 230 VAC), making it suitable for various installations.